IDP Smart 70 Multi termination Error (internal only)

Modified on Tue, 09 Mar 2021 at 05:23 PM


1. check the connection between the Interface board and mainboard. If it is loose, it may occur. (back panel needs removing)


2. It is a rare case but the replaced interface board may be also damaged.

 Please replace it again.


3. I didn't get the cause is the mainboard or cable between the MB and interface board, but please replace them  and test it again.


4. To check the issue port of Red cable,


 Please connect the issued SMART-70P to the Input hopper only, and then connect it to the Output hopper only. (IP / PO combination)


 By this test, you can find the issued port.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select atleast one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article